Inicio
  • Sitios Web Belimo

    América

    • Brasil
    • Canadá
    • Caribe, América Latina y Estados Unidos

    Europa, Oriente Medio y África

    • Albania
    • Alemania
    • Arabia Saudita
    • Austria
    • Bélgica
    • Bielorusia
    • Bosnia-Herzegovina
    • Bulgaria
    • Croacia
    • Dinamarca
    • Emiratos Árabes Unidos
    • Eslovaquia
    • Eslovenia
    • España
    • Estonia
    • Finlandia
    • Francia
    • Georgia
    • Grecia
    • Holanda
    • Hungría
    • Irlanda
    • Israel
    • Italia
    • Kazastán
    • Letonia
    • Lituania
    • Macedonia del Norte
    • Noruega
    • Polonia
    • Reino Unido
    • República Checa
    • Rumanía
    • Serbia y Montenegro
    • Sudáfrica
    • Suecia
    • Suiza
    • Turquía
    • Ucrania

    Asia-Pacífico

    • Australia
    • Camboya
    • China
    • Corea
    • Filipínas
    • Hong Kong, China
    • India
    • Indonesia
    • Japón
    • Macao, China
    • Malasia
    • Myanmar
    • Nueva Zelanda
    • Singapur
    • Tailandia
    • Taiwán, China
    • Vietnám
    Español

    Deutsch

    Français

    English

    中文

    Português

    Español

    Español

    Français

    Italiano

    Nederlands

    Türkçe

    Polski

    Norsk

    Suomalainen

    Svenska

    English

    Magyar

    Eesti keel

    Русский

    Latviski

    Lietuvių

    български

    language.el_GR

    עִברִית

    Română

    Slovenščina

    Slovenský

    Srpski

    Mакедонски

    Hrvatski

    Shqiptare

    Srpski

  • Sitios Web Belimo

    América

    • Brasil
    • Canadá
    • Caribe, América Latina y Estados Unidos

    Europa, Oriente Medio y África

    • Albania
    • Alemania
    • Arabia Saudita
    • Austria
    • Bélgica
    • Bielorusia
    • Bosnia-Herzegovina
    • Bulgaria
    • Croacia
    • Dinamarca
    • Emiratos Árabes Unidos
    • Eslovaquia
    • Eslovenia
    • España
    • Estonia
    • Finlandia
    • Francia
    • Georgia
    • Grecia
    • Holanda
    • Hungría
    • Irlanda
    • Israel
    • Italia
    • Kazastán
    • Letonia
    • Lituania
    • Macedonia del Norte
    • Noruega
    • Polonia
    • Reino Unido
    • República Checa
    • Rumanía
    • Serbia y Montenegro
    • Sudáfrica
    • Suecia
    • Suiza
    • Turquía
    • Ucrania

    Asia-Pacífico

    • Australia
    • Camboya
    • China
    • Corea
    • Filipínas
    • Hong Kong, China
    • India
    • Indonesia
    • Japón
    • Macao, China
    • Malasia
    • Myanmar
    • Nueva Zelanda
    • Singapur
    • Tailandia
    • Taiwán, China
    • Vietnám
  • DE FR EN 中文 PT ES ES FR IT NL TR PL NO FI SE EN HU ET RU LV LT BG EL HE RO SL SK SR MK HR SQ BA
Inicio
belimo_4-Chilled-Beam_1920x350px

Viga fría

  1. Inicio
  2. Belimo Energy Valve™ y Medidor de Energía Térmica
  3. Aplicaciones HVAC

Belimo Energy Valve™ in Chilled Beam applications

¿Qué es una viga fría?

Una viga fría es un tipo de sistema de convección de HVAC diseñado para calentar y enfriar ambientes, normalmente implementado en edificios de oficinas de planta abierta. Los tubos pasan a través de una "viga" (un intercambiador de calor), ya sea directamente integrada en el techo suspendido, o colgada bajo el techo suspendido de una sala.

Actualmente se utilizan dos tipos de vigas frías:

  • Una viga pasiva enfría el aire a su alrededor y forma una corriente de convección natural en la que el aire enfriado cae y el aire calentado se eleva para sustituirlo, enfriando así el ambiente.
  • Las vigas frías activas también se usan de forma común y utilizan el aire de una unidad manejadora de aire para inducir un flujo de aire adicional sobre la viga.

El principal desafío de esta aplicación es el control de la temperatura del agua y el flujo, garantizando que la temperatura superficial de la viga no caiga por debajo del punto de rocío del ambiente.

Esquema

chilled-beam-schematic

La imagen muestra el diagrama de una aplicación de viga fría con una Energy Valve. Esto proporciona la siguiente funcionalidad de control:

  • Medición precisa del flujo y la temperatura de alimentación y retorno
  • Monitoreo y control de la potencia térmica de la unidad
  • Balanceo hidrónico permanente del flujo de agua con cambios en la presión del sistema y con cualquier condición de carga
  • Integración opcional de un interruptor que sensa el punto de rocío
  • El diferencial de temperatura necesario en las vigas frías es muy bajo, lo que hace que su control resulte esencial


Order the new Belimo Energy Valve™ now

Learn how the Energy Valve improves your chilled beam





Energy Valve
Shop now




Problemas comunes en aplicaciones de viga fría y por qué debería elegir la Belimo Energy Valve™

Large chilled water systems are dynamic in nature, with pressure fluctuations caused by pump speed and valve position changes. Statically balanced systems, as the name suggests, are unable to deal with these dynamic changes and, as a result, flow rates through each unit fluctuates with pressure changes.
The dynamic balancing function of a pressure independent valve handles pressure fluctuations in the system, and assures that the flow is maintained on the defined setpoint.

Dynamic Balancing of a Chilled Beam


Low water temperatures and insufficient humidity control can lead to condensate forming on the chilled beam, and can subsequently damage furniture of office equipment that can be costly. However, conservative supply water temperatures can result in insufficient cooling capacity.



Condensation of humid air on the cold coil surface. The supplied cooling water needs to be above the indoor dew point to prevent condensation

Using the more accurate and responsive immersion flow sensor from the Belimo Energy Valve™, DDC systems are able to detect and close-off water flows before condensate forms on the chilled beams. Reliable data from both the space and the water temperatures is the key to maximising chilled beam performance, while minimising the risk of condensate forming. An outdoor humidity/temperature sensor, such as the Belimo 22UTH-11, can be used to measure the outdoor air conditions and to adapt the AHU-control accordingly.

Supply air into the occupied space, and the circulated air from the room, pass over the coils of the chilled beam. The indoor dew point must be maintained below the surface temperature of the chilled beam coil to prevent condensation water dropping from the ceiling.

The primary air system in the AHU is used to offset the space latent load, and it typically maintains the indoor dew point at or below 13 °C [55 °F] to prevent condensation. Also, the water temperature delivered to the beams is typically maintained between 14 °C [58 °F] and 16 °C [60 °F], sufficiently above the dew point of the space.

Consejo profesional

Consulte los estándares locales relativos a las temperaturas de aire y valores de humedad ambiental recomendados (o los valores máximos), así como las temperaturas del agua de enfriamiento recomendadas. Si las cargas de enfriamiento en la sala o en grandes superficies de enfriamiento son menores, las temperaturas del agua helada pueden aumentarse algunos grados (por ejemplo, hasta 18 °C). Es posible mantenerse el enfriamiento suficiente en la sala y, adicionalmente, realizarse la deshumidificación con un método que ahorre energía.

Ejemplo de aplicación

In the figure, a Chilled Beam is not working as expected. Design water flow should be 0.12 l/s [1.9 GPM], with delta T at 3 °C [1.5 °F], and a differential pressure across the loop of 1 bar [14.5 PSI]. However, due to the pressure changes in the system, delta P increases from 1 to 2 bar [14.5 to 29 PSI], and different loads are needed. The chilled beam is receiving 25% more water than design. This results in poor comfort in the ambient and lowers the efficiency of the heat transfer.

Chilled beam with a pressure dependent valve
Using the mechanical pressure independent valve, PIQCV, guarantees the design flow 0.12 l/s [1.9 GPM], even when pressure fluctuations happen in the system. This results in better control and comfort.

Chilled beam using a mechanical PI valve

The Energy Valve will keep the flow as designed regardless of pressure fluctuations, at 0.12 l/s [1.9 GPM]. It will also manage the delta T over the coil and provide all essential data regarding flow, temperatures and energy to the BMS. Using the data available from the EV, many other value-added features are available, such as early detection of likely condensate issues.



Chilled beam using an Energy Valve

As shown below, the Energy Valve is on the same network as the sensor and the BMS head-end PC. The BMS is looking at the water flow temperature and calculating the dew point, using the RH and temperature data from the room unit. The BMS has seen the entering water temperature is at dew point, and has commanded the valve to close, in order to prevent condensate forming on the unit. The Delta T manager will keep your beams optimized when air flows over the coil vary.



Chilled beam using an Energy Valve, with the BMS calculating the dew point with the input from a room sensor

Realice el pedido de la Belimo Energy Valve™ en nuestra tienda en línea

  • Compre ahora

Descubra más acerca de la Belimo Energy Valve™

  • Más información

La Belimo Energy Valve™ en otras aplicaciones HVAC

  • Más información

Bienvenido a Belimo {{js-currentCountryName}}

{{js-currentCountryText}}
Contáctenos Política de privacidad Cambiar la configuración de privacidad
'+41 43 843 61 11
Suscribir
BELIMO Holding AG, Brunnenbachstrasse 1, 8340 Hinwil (Suiza)